Education > EXAM > IICL Container Inspector's Exam MULTIPLE CHOICE QUESTIONS & ANSWERS, MOSTLY TESTED QUESTIONS WITH 10 (All)
IICL Container Inspector's Exam MULTIPLE CHOICE QUESTIONS & ANSWERS, MOSTLY TESTED QUESTIONS WITH 100% VERIFIED ANSWERS-Which of the following defects requires repair? A. A loose door gasket B. ... A bent J-bar that does not affect door operation C. A dent 13mm (1/2 in) deep on the door sill D. Four dents, each 11mm (7/16 in) deep, on contiguous outboard corrugations of a roof panel - A. A loose door gasket Of the following conditions in a dry-van container, which one would require cleaning? A. Raised mud foot prints in excess of what might normally remain after a sweep out B. Dry dust covering dried floor stains as might normally be found after a sweep out C. Coffee beans remaining inside the container as might occur after a sweep out D. Polyurethane beads as might be expected to lodge in grooves between floorboards after a sweep out - C. Coffee beans remaining inside the container as might occur after a sweep out An Equipment Interchange Receipt (EIR), based on an inspection with no damage found, can be evidence of a container's compliance with: A. Australian Timber Component Treatment Regulations B. Convention for Safe Containers (CSC) regulations through the ACEP Program C. Transport under custom's seal (TIR) regulations D. International Standards Organization (ISO) CEDEX codes regulations - B. Convention for Safe Containers (CSC) regulations through the ACEP Program The top of a replacement plastic ventilator should be centered what distance from the top side rail? A. 50-55mm (2-2 3/16 in) B. 70-75mm (2 5/8 - 3 in) C. 100mm (4in) D. 150mm (6 in) - A. 50-55mm (2-2 3/16 in) When must a reference line extend the full length of a bottom side rail? A. When there are two or more areas of damage on the bottom side rail B. When there is a sharp bend in the bottom side rail C. When there is a bowing over the entire bottom side rail D. When there is additional damage to the bottom side rail so that the reference line cannot be positioned over the ends of the damage - C. When there is a bowing over the entire bottom side rail Which of the following is NOT a transverse structural member of the container? A. Front sill B. Tunnel rail C. Rear header D. Crossmember - B. Tunnel rail A steel corner fitting is being replaced. To ensure better weld penetration, IICL recommends that the edges of parts adjacent to the corner fitting be ground to a minimum bevel of? A. 30 degrees B. 45 degrees C. 55 degrees D. 60 degrees - B. 45 degrees Which of the following components is sometimes placed longitudinally in the container to support plywood flooring? A. Transverse bow B. Gusset C. Hat section center spacer D. Threshold plate - C. Hat section center spacer [Show More]
Last updated: 1 year ago
Preview 5 out of 25 pages
Loading document previews ...
Buy this document to get the full access instantly
Instant Download Access after purchase
Buy NowInstant download
We Accept:
Can't find what you want? Try our AI powered Search
Connected school, study & course
About the document
Uploaded On
Dec 09, 2024
Number of pages
25
Written in
All
This document has been written for:
Uploaded
Dec 09, 2024
Downloads
0
Views
28
Scholarfriends.com Online Platform by Browsegrades Inc. 651N South Broad St, Middletown DE. United States.
We're available through e-mail, Twitter, and live chat.
FAQ
Questions? Leave a message!
Copyright © Scholarfriends · High quality services·