CTEC 1391 Test Prep
Explain the function of an I/p in a control loop. What usually connected to - ✔✔Flow transducer
converts to (4-20mA) signal from the controller to (3-15psig) pneumatic signal which sends the
valve
...
CTEC 1391 Test Prep
Explain the function of an I/p in a control loop. What usually connected to - ✔✔Flow transducer
converts to (4-20mA) signal from the controller to (3-15psig) pneumatic signal which sends the
valve to open or close
What would the pump system control valve would do if HV-201 were to close - ✔✔Open the
bypass which is HV-202
If the flow transmitter (FT-102) in the tank system would have faulty reading of 0 the tank level
on LIC-101 would change by - ✔✔Everything would increase
If the flow transmitter (FT-102) in the tank system would have faulty reading of 0 the flow
through FIC-101 would change by - ✔✔Would not change
If the flow transmitter (FT-102) in the tank system would have faulty reading of 0 the output
signal on LIC-101 and the setpoint of FIC-103 would change by - ✔✔FIC-102 would close
If HV-101 were to fail in the tank system the output signal on LIC-101 and flow of FIC-102
would change by - ✔✔It would decrease.
Explain the purpose of the reboiler and how it works - ✔✔Shell of tube of the reboiler and heats
the thermoil
Explain the purpose of reflux - ✔✔Vapor comes up to the top cools down the temperature turns
it to liquid.
If feed were to increased to the tower what would happen to the thermoil flow - ✔✔It would go
down
If the preheater temperature were to increase in SPM 700 how would the reflux flow valve (FV801) and (AI-801) change - ✔✔It would go up, and get hotter, would vapor more, TIC-308
increase temperature, FV-801 should open up
Lost of cooling water in SPM 700 to the condenser how would (FV-802) change - ✔✔Decrease
flow, cooling water to the drum,
Combination reaction - ✔✔A+B-->C
Decomposition reaction - ✔✔C->A+B
Single Replacement reaction - ✔✔AB+C->AC+B
Double Replacement reaction - ✔✔AB + CD --> AD + CB
If a reaction is exothermic and we want to keep the temperature constant, what must we do -
✔✔Cool the reactor
A stirred tank reactor reacts M+N>O M and N are both flow controlled into the reactor and the
reactor is level controlled by letting the product out If M is limited reagent which is most
effective increasing production rate of O - ✔✔Increasing flow of M by 5%
If I increased the temperature of a reactor by 10 Cel would reaction go faster or slower -
✔✔Faster, higher the temperature faster the reaction.
If I had a highly exothermic reaction and needed to remove a lot of heat effectively what type of
reactor would be best. - ✔✔Tubular (quicks to transfer heat)
Name three ways you could increase the conversion in SPM 2100 - ✔✔Increase the temperature
setpoint
Increase the speed mixture
Increase the flow rate of reactant A to B
If the agitator speed in SPM 2100 is increased which direction would you expect TIC 223 output
to change - ✔✔Decreases the output to open the valve
If the agitator speed is increased in SPM 2100 which direction would AI-223 change - ✔✔It
would increase
If the agitator speed is increased in SPM 2100 which direction would FIC-211 output change -
✔✔There would not be a change
Why does increasing the flow of reactant A require less cooling / more heating if the reaction is
exothermic - ✔✔Would cause more heating
Doing Laundry batch or continuous - ✔✔Batch
Brewing coffee batch or continuous - ✔✔Batch
Propane burner on grill reacting propane and air batch or continuous - ✔✔Continuous
Traffic flow at stop light batch or continuous - ✔✔Batch
Traffic flow at traffic circle batch or continuous - ✔✔Continuous
Burning fuel inside cylinder of 4 stroke gasoline engine batch or continuous - ✔✔Batch
Burning fuel inside a gas turbine jet engine batch or continuous - ✔✔Continuous