SCBA BOOK QUIZ
What is the function of the heads-up display (HUD) on the SCBA facepiece assembly? -
✔✔Displays lights that indicate the amount of air left in the SCBA cylinder
Prior to donning SCBA, firefighters shoul
...
SCBA BOOK QUIZ
What is the function of the heads-up display (HUD) on the SCBA facepiece assembly? -
✔✔Displays lights that indicate the amount of air left in the SCBA cylinder
Prior to donning SCBA, firefighters should: - ✔✔check the air cylinder gauge to make sure the
cylinder is full.
Your point of no return is based on: - ✔✔the lowest cylinder gauge reading of any member of
the team.
Side- or rear-mounted SCBA: - ✔✔are mounted on the exterior of the apparatus.
Which SCBA component attaches to the SCBA facepiece and directly controls airflow to the
wearer? - ✔✔Regulator
What is a general guideline for donning an SCBA facepiece? - ✔✔Center the harness at the rear
of the head.
What should a firefighter do if an SCBA inspection reveals that repairs are necessary? -
✔✔Immediately report the needed repairs to the appropriate person
When refilling an SCBA cylinder, firefighters must: - ✔✔ensure that the cylinder is completely
full, but not overpressurized.
Which piece of PPE should be worn during structural fire fighting operations? - ✔✔Protective
hood
Situations or events that signal the need for exit are called: - ✔✔exit indicators
If storing SCBA in seat mounts, be sure to: - ✔✔arrange the SCBA so it can be donned without
removing your seat belt.
On an SCBA air cylinder, the pressure gauge is used to: - ✔✔display the amount of air left in the
cylinder.
Factors that firefighters have the most control over that affect the success of SCBA use include
physical condition, agility, and: - ✔✔. lung capacity.
Which SCBA limitation would a firefighter be able to overcome through physical fitness and
regular medical evaluations? - ✔✔Insufficient lung capacity
Which statement about replacing SCBA cylinders is MOST accurate? - ✔✔Changing out SCBA
cylinders can be accomplished by either one or two people.
Which statement describes the function of an auto-cascade system? - ✔✔Completely automated
fill station that fills air cylinders to a programmable pressure
What is a general safety precaution to take when refilling an SCBA cylinder? - ✔✔Check the
hydrostatic test date of the cylinder
Donning SCBA from a seat mount should only be done if: - ✔✔it can be accomplished without
removing the apparatus seat belt
What is an effective way to protect yourself from the health hazards caused by inhaling smoke
and other products of combustion? - ✔✔Wear respiratory protection
Which situation would be classified as an emergency exit indicator that would signal the need to
leave the hazardous or contaminated area immediately? - ✔✔SCBA failure
What should be done after doffing SCBA? - ✔✔Close the cylinder valve.
Which guidelines should be followed when using SCBA? - ✔✔Only enter an IDLH atmosphere
if you have been certified to wear SCBA and properly fit tested.
Under normal conditions, air management increases your work time, but if you are lost or
trapped, it: - ✔✔increases the amount of time you can survive before escaping or being rescued.
Which SCBA component includes a control valve and a high-pressure hose attached to one end?
- ✔✔Air cylinder
SCBA can help protect from _____, which can be caused by inhaling heated gases. -
✔✔asphyxiation
What is the primary type of respiratory protection used in the fire service? - ✔✔Atmospheresupplying respirator (ASR)
After doffing SCBA, always remember to: - ✔✔clean and disinfect the facepiece.
Hazardous materials incidents can involve potentially dangerous nonfire gases and vapors, so
firefighters must: - ✔✔wear SCBA until air monitoring demonstrates that the atmosphere is safe.
While using SCBA, always remember to: - ✔✔frequently check the air supply status
Which emergency exit indicator would signal the need to immediately exit the hazardous area? -
✔✔Activation of the SCBA low-pressure air alarm
What are mobile fill stations designed to do? - ✔✔Refill air cylinders during emergency
incidents
Which type of breathing air source would be found inside a high-rise building? - ✔✔Firefighter
Breathing Air Replenishment System
Immediately prior to donning SCBA, firefighters should: - ✔✔check the cylinder gauge to make
sure the cylinder is full.
Which SCBA equipment limitation would MOST directly impact a firefighter's ability to
navigate on scene? - ✔✔Limited visibility
Actions such as opening a bypass valve on a cylinder, sharing air, and breathing directly from the
cylinder are: - ✔✔possible solutions to air emergencies
Who is usually in charge of performing annual SCBA inspection and maintenance? -
✔✔Factory-qualified technician
The end-of-service-time indicator (EOSTI): - ✔✔. uses an audible alarm and flashing light or
vibration to warn the wearer that the air supply is almost depleted.
Open-circuit SCBA models: - ✔✔provide compressed air to the wearer.
Which piece of respiratory equipment provides insufficient protection against airborne
pathogens? - ✔✔Surgical masks
Firefighters should wear SCBA in hazardous atmospheres, because exposure to particulate
contaminants such as _____ can cause lung cancer or cardiovascular disease. - ✔✔vehicle
exhaust emissions
In a situation such as a confined space rescue where a team member must work alone, the second
team member should: - ✔✔remain outside the area and monitor the search line.
When exchanging an empty SCBA air cylinder for a full cylinder, remember to: - ✔✔keep
empty cylinders separate from full cylinders
Which situation would likely be granted an exception to the rule that prohibits filling an
unshielded air cylinder while a firefighter is wearing the SCBA? - ✔✔A rapid intervention crew
(RIC) is rescuing a trapped or incapacitated firefighter.
According to the buddy system, - ✔✔firefighters must work in teams of at least two members in
all hazardous situations.
How do firefighter breathing air replenishment systems make fire fighting operations in high-rise
buildings more efficient? - ✔✔provide an endless supply of breathing air to any floor within the
structure
After each use, the SCBA facepiece should be: - ✔✔washed with warm water and a mild
disinfectant.
How can firefighters overcome limitations caused by SCBA weight and decreased mobility? -
✔✔train with units they will use on the fire ground
Which SCBA component includes a speaking diaphragm that allows firefighters to communicate
with teammates? - ✔✔Facepiece assembly
In order to stay as safe as possible while wearing SCBA, it is important to: - ✔✔keep SCBA on
and activated until you leave the IDLH area.
Which situation would likely have an oxygen-deficient atmosphere in which respiratory
protection would be necessary? - ✔✔Rescue in a sewer
When should you check your SCBA gauge to see how much air you have left? - ✔✔when the
assigned area is reached
Seat-mounted SCBA: - ✔✔allow FF to don the SCBA while still inside the apparatus
How do controlled breathing techniques benefit firefighters? - ✔✔Slows breathing and extends
the time it takes to deplete air in the SCBA cylinder
Which SCBA component controls air flow from the cylinder when the regulator fails? -
✔✔Bypass valve
If the pressure reading on the remote pressure gauge does not match the reading on the regulator
gauge, which reading should be assumed correct? - ✔✔the lowest number reading
The SCBA backplate and harness assembly: - ✔✔is used to hold the breathing air cylinder.
Panic, claustrophobia, and disorientation are effects of: - ✔✔obscured vision conditions
Which of the following is one of the three principles of air management? - ✔✔Know your point
of no return.
When donning an unmounted SCBA, the SCBA unit should be: - ✔✔placed on the ground with
all of the straps extended.
A daily/weekly inspection of SCBA should include: - ✔✔check of the regulator and facepiece.
What should you do if you experience symptoms of oxygen deficiency such as light-headedness
or loss of coordination? - ✔✔Report symptoms and immediately evacuate the area
Airborne pathogens may cause illness through inhalation or: - ✔✔direct contact.
Which SCBA component allows the air cylinder to be transfilled from another cylinder in the
event of an emergency? - ✔✔Rapid intervention crew universal air coupling (RIC UAC)
Annual SCBA inspections and maintenance should be performed by: - ✔✔specially trained,
factory-qualified technicians.
How can a firefighter overcome psychological limitations such as fear and claustrophobia while
wearing SCBA? - ✔✔Repeated training with the SCBA
How can firefighters protect themselves against health hazards caused by inhaling smoke and
other products of combustion? - ✔✔Wearing respiratory protection equipment
[Show More]