Optometry  >  QUESTIONS & ANSWERS  >  NCLE Prep Exam 3 of 4 (All)

NCLE Prep Exam 3 of 4

Document Content and Description Below

NCLE Prep Exam 3 of 4 The tolerance for the overall lens diamter according to the ANSI standards is: A. +/-0.005mm B. +/-0.05mm C. +/-0.01mm D. +/-0.1mm - ✔✔B. According to the ANSI standard ... s (Z80.2-1989), the tolerance for the overall diameter of a contat lens is +/-0.05mm. ANSI standards have been developed to maintain quality in the contact lens industry. It is important to have an understanding of the ANSI guidelines. All of the following will enable the practitioner to verify the overall rigid gas permeable lens diameter except: A. Slot gauge B. Shadowgraph C. Measuring magnifer D. Radiuscope - ✔✔D. Radiuscope The slot gauge, shadowgraph and measuring magnifier will all enable the practitioner to verify the overall lens diameter of rigid gas permeable lens. The radiuscope is an instrument that will measure the base curve of a rigid lens. Placing the concave side of a rigid gas permeable lens against the lens stop of the lensometer, will provide you with which of the following? A. Back vertex power B. Front vertex power C. Best vertex power D. Closest vertex power - ✔✔A. Back vertex power By placing the back (posterior) surface of the rigid gas permeable lens against the lens stop, the reading that results will be in back vertex power An instrument that allows simultaneous verification of lens diameter, optic zone width and peripheral curve width is: A. Measuring magnifier B. Ophthalmometer C. Profile analyzer D. Radiuscope - ✔✔A. Measuring magnifier An ophthalmometer, another name for the keratometer, cannot measure the listed parameters. The profile analyzer evaluates the peripheral curve blends and the radiuscope measures the base curve of the rigid contact lens. The measuring magnifier is the only instrument that will measure the parameters listed. Assessment of the quality of the peripheral curves (blends) of a rigid contact lens is achievable by the use of the: A. Profile analyzer B. Shadowgraph C. Profile analyzer D. Burton lamp - ✔✔A. Profile analyzer All of the listed instruments show that a rigid contact lens has blends. However, the only instrument that can adequately assess the quality of the blends between the peripheral posterior curve (PPC), intermediate posterior curve (IPC) and the central posterior curve (CPC), is the profile analyzer. The instrumental used for magnification of the edge of a rigid contact lens is a: A. Keratometer B. Shadowgraph C. Profile analyzer D. V-groove gauge - ✔✔B. Shadowgraph A keratometer measures the corneal curvature. A profile analyzer measures the peripheral curves (blends) and a v-groove gauge measures the diameter of a rigid contact lens. The tolerance for lens power under +/-10.00D is: A. 0.12D B. 0.25D C. 0.37D D. 0.50D - ✔✔A. 0.12D According to the ANSI standards (Z80.2 - 1989), the tolerance for the power of a contact lens under +/-10.00D is +/-0.12D Which of the following will NOT measure contact lens parameters? A. Keratometer B. Radiuscope C. Burton lamp D. Thickness gauge - ✔✔A keratometer will measure the base curve of a lens with an attachment known as a con-ta-check; however, a radiuscope is most frequently used. A thickness gauge will measure the center thickness of a contact lens. A burton lamp evaluates the fluorescein pattern similar to a slit lamp. A warped lens will show ________ base curve(s) on the radiuscope and a ________ power on the lensometer. A. One / sphero-cylindrical B. Two / sphero-cylindrical C. One / sphero-cylindrical D. Two / spherical - ✔✔D. Two / spherical Verification should show the following: Lens type - Radiuscope - Lensometer Spherical - One base curve - Spherical Rx Warped - two base curves - spherical rx Front toric - one base curves - sphero-cylindrical rx Back toric - two base curves - sphero-cylindrical rx Bi-toric - two base curves - sphero-cylindrical rx Prolonged periods of reading in contact lenses may lead to lens discomfort due to: A. Decreased blinking B. Corneal temperature changes C. Accommodative response D. Neovasularization - ✔✔A. Decreased Blinking When a patient spends a great deal of time reading or any other activity in which they are intently staring at an object (watching tv, driving, etc.) they may experience some discomfort as their blink rate drops and new tears are not exchanged for old tears underneath the lens Which of the following statements is most accurate: A. Routine cosmetic daily wear patients should be seen at 3 month intervals for a contact lens evaluation B. Patients with a history of GPC should be refit with disposable soft lenses and followed on a bi-weekly basis for 6 months C. New soft lens fits should be seen one week, one month, three months and 6 months from the time their initial fit, then every 6 to 12 months D. Patients who are wearing RGP lenses after penetrating keratoplasty need fewer follow-up visits than keratoconus patients because their corneas are now spherical - ✔✔C. Choice A would be correct only for patients who have already gone through the sequence of follow-up care recommended for new contact lens wearers as outlined in Choice C. Choice B involves an excessive number of follow-up visits which can be inconvenient for the patient and impractical for the practitioner. If the GPC is so severe that the patient must return every two weeks, they are not yet ready to be refit with contact lenses. Choice D is incorrect because it is rare that a penetrating keratoplasty results in a spherical cornea and post-graft patients tend to be more difficult to fit with contact lenses. One must also watch the graft/host junction closely for problems Which of the following materials would least likely require a weekly enzymatic cleaner? A. Polymethylmethacrylate B. Hydrophilic C. Hydroxyethyl Methacrylate D. Silicone acrylate - ✔✔A. Polymethylmethacrylate All of the other lens materials are recommended to be cleaned weekly with an enzymatic cleaner. Which type of lens would best satisfy this patient's visual needs given the following information: K's 43.00 @ 160 / 44.00 @ 75 3+ distortion [Show More]

Last updated: 3 years ago

Preview 1 out of 20 pages

Buy Now

Instant download

We Accept:

Payment methods accepted on Scholarfriends (We Accept)
Preview image of NCLE Prep Exam 3 of 4 document

Buy this document to get the full access instantly

Instant Download Access after purchase

Buy Now

Instant download

We Accept:

Payment methods accepted on Scholarfriends (We Accept)

Reviews( 0 )

$10.00

Buy Now

We Accept:

Payment methods accepted on Scholarfriends (We Accept)

Instant download

Can't find what you want? Try our AI powered Search

148
0

Document information


Connected school, study & course


About the document


Uploaded On

Jul 08, 2022

Number of pages

20

Written in

All

Seller


Profile illustration for Nutmegs
Nutmegs

Member since 4 years

607 Documents Sold

Reviews Received
77
14
8
2
21
Additional information

This document has been written for:

Uploaded

Jul 08, 2022

Downloads

 0

Views

 148

Document Keyword Tags


$10.00
What is Scholarfriends

Scholarfriends.com Online Platform by Browsegrades Inc. 651N South Broad St, Middletown DE. United States.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Scholarfriends · High quality services·